dc.description.abstractAo longo da presente dissertação procedeu-se ao estudo de estruturas celulares recorrendo a ensaios experimentais estáticos e dinâmicos. Os principais focos do trabalho passaram pela validação deste tipo de estruturas e pela avaliação das mesmas sob o ponto de vista de melhoria das suas propriedades mecânicas. As estruturas celulares híbridas em estudo consistiram em vigas retangulares bi-material constituídas por ácido polilático e elastómero. O desempenho destas estruturas foi então analisado comparativamente com aquele evidenciado por provetes maciços e ocos com dimensões gerais equivalentes e ambos constituídos exclusivamente por ácido polilático. O processo de fabrico utilizado para a obtenção de todos os provetes foi a manufatura aditiva. Relativamente aos ensaios experimentais estáticos realizados, procedeu-se ao ensaio de tração de provetes maciços para validação de propriedades do material e ao ensaio de flexão de exemplares das três diferentes geometrias como forma de determinar a rigidez de cada um deles. De referir que a configuração deste segundo tipo de ensaio consistiu numa viga em consola. No caso dos ensaios dinâmicos, a configuração descrita foi mantida, mas ao invés de uma carga aplicada gradualmente na extremidade livre da viga, a solicitação consistiu apenas num impacto para assim poder registar a sua resposta livre. Os ensaios de tração revelaram a necessidade em desenvolver normas específicas para validação de propriedades de materiais obtidos por manufatura aditiva, visto que este tipo de estruturas evidencia um comportamento anisotrópico. Os ensaios de flexão evidenciaram um valor de rigidez superior no provete oco, seguido do provete maciço e do bi-material. Por sua vez, os ensaios dinâmicos revelaram maior amortecimento do provete maciço, seguido pelos provetes oco e bi-material, ambos com desempenhos semelhantes. Na sua generalidade, os modelos numéricos desenvolvidos revelaram sempre uma replicação satisfatória dos valores obtidos através dos ensaios experimentais realizados. Refletindo por último sobre o desempenho revelado pela estrutura celular híbrida em estudo, a mesma não revelou ser uma escolha vantajosa face aos outros provetes visto que foi aquela que apresentou menor valor de rigidez e amortecimento.por
dc.description.abstractThroughout this dissertation, the study of cellular structures was carried out using static and dynamic experimental tests. The main focus of the work was the validation of this type of structures and their evaluation from the perspective of improving their mechanical properties. The hybrid cell structures under study consisted of bi-material rectangular beams made up of polylactic acid and elastomer. The performance of these structures was then analyzed in comparison with that evidenced by solid and hollow polylactic acid specimens with equivalent general dimensions. The manufacturing process used to obtain all the specimens was additive manufacturing. Regarding the static experimental tests carried out, the aim of the tensile test of solid specimens was to validate the material properties, while the stiffness of each one of the three different geometries was obtained through the bending tests. It should be noted that the configuration of this second type of test consisted of a cantilevered beam. Concerning the dynamic tests, the described configuration was maintained, but instead of a load gradually applied to the free end of the beam, the solicitation consisted only of an impact in order to register the free response of the beam. The tensile tests revealed the need to develop specific standards to validate the properties of materials obtained by additive manufacturing, since this type of structures reveals an anisotropic behavior. The bending tests showed a higher stiffness value for the hollow specimen, followed by the solid specimen and the bi-material one. On the other hand, the dynamic tests revealed greater damping of the solid specimen, followed by the hollow and bi-material specimens, both with similar performances. In general, the numerical models developed always revealed a satisfactory replication of the values obtained through the experimental tests. Finally, reflecting on the performance revealed by the hybrid cell structure under study, it did not prove to be an advantageous choice compared to the other specimens, since it was the one that presented the lowest stiffness and damping values.por
dc.language.isoporpor
dc.rightsopenAccesspor
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/por
dc.subjectAmortecimentopor
dc.subjectImpressão 3dpor
dc.subjectPLApor
dc.subjectRigidezpor
dc.subjectVigaspor
dc.subjectDampingpor
dc.subject3D printingpor
dc.subjectStiffnesspor
dc.subjectBeamspor
dc.titleValidação experimental de conceito de estruturas celulares híbridaspor
dc.typemasterThesiseng
dc.identifier.tid202790282por
thesis.degree.grantorUniversidade do Minhopor
sdum.degree.grade18 valorespor
sdum.uoeiEscola de Engenhariapor
dc.subject.fosEngenharia e Tecnologia::Engenharia Mecânicapor
Aparece nas coleções:BUM - Dissertações de Mestrado
DEM - Dissertações de Mestrado / MSc Thesis

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
Miguel Vila Ferreira.pdfDissertação de mestrado56,88 MBAdobe PDFVer/Abrir

Este trabalho está licenciado sob uma Licença Creative Commons Creative Commons

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID