Título: | Estudo experimental do desempenho de um sistema coagulação - filtração de água |
Outro(s) título(s): | Experimental study of the performance of a system coagulation - filtration of water |
Autor(es): | Quaresma, João Luís Pinto Leite |
Orientador(es): | Silva, Júlio F. Ferreira da |
Palavras-chave: | Saúde pública Tratamento de água Coagulação - floculação Filtros de areia Coagulantes orgânicos Sulfato de alumínio Public health Water treatment Coagulation - flocculation Sand filters Organic coagulants Aluminium sulphate |
Data: | 2013 |
Resumo(s): | Esta dissertação teve como principal objetivo o desenvolvimento de estudos experimentais
sobre o desempenho de um sistema de coagulação / filtração no tratamento de água. Para
melhor conhecer a realidade, foram utilizados alguns coagulantes existentes no mercado
(sulfato de alumínio, polímeros orgânicos, inorgânicos e misturas de ambos), totalizando 9
coagulantes diferentes.
O sulfato de alumínio é o coagulante mais utilizado no mercado devido à sua eficiência de
coagulação, fácil manuseamento e transporte, e baixos custos.
Os ensaios foram realizados utilizando um aparelho de “Jar-Test”, fazendo variar numa 1ª
fase as dosagens de coagulante, assim como os tempos de mistura. Numa 2ª fase foi variada a
dosagem do coagulante e a turvação inicial da água.
Após cada experiência, a água era filtrada e de imediato eram medidos os valores dos
parâmetros indicadores de qualidade analisados.
Foi desta maneira possível examinar o desempenho dos diversos coagulantes face a diferentes
turvações da água bruta. This dissertation aimed to the development of experimental studies on the performance of a system of coagulation / filtration in water treatment. To better know the reality, coagulants available in the general market (aluminium sulphate, organic polymers, inorganic and mixtures thereof) were used, in a total of nine different coagulants. Aluminium sulfate is the most commonly used coagulant due to its coagulation efficiency, ease of handling and transport, and low cost. The tests were conducted using a "Jar-Test" apparatus and varying in a 1st stage the coagulant dosages, as well as mixing times. In the 2nd Stage, coagulant dosage and the initial turbidity of the water were varied. After each experiment, the water was filter and the values of the quality of the water parameters were measured. This made possible to assess the ability of various coagulants using different raw water turbidities. |
Tipo: | Dissertação de mestrado |
Descrição: | Dissertação de mestrado integrado em Engenharia Civil (área de especialização em Perfil de Hidráulica e Ambiente) |
URI: | https://hdl.handle.net/1822/30764 |
Acesso: | Acesso aberto |
Aparece nas coleções: | BUM - Dissertações de Mestrado C-TAC - Dissertações de Mestrado |
Ficheiros deste registo:
Ficheiro | Descrição | Tamanho | Formato | |
---|---|---|---|---|
Dissertação_João Quaresma_2013.pdf | 2,06 MB | Adobe PDF | Ver/Abrir |