Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/26582

Registo completo
Campo DCValorIdioma
dc.contributor.authorBrito, F. P.-
dc.contributor.authorMartins, Jorge-
dc.contributor.authorGonçalves, L. M.-
dc.contributor.authorAntunes, Nuno-
dc.contributor.authorSousa, Diogo-
dc.date.accessioned2013-12-03T11:06:54Z-
dc.date.available2013-12-03T11:06:54Z-
dc.date.issued2013-07-
dc.identifier.citationF. P. Brito, Jorge Martins, L.M. Goncalves, Nuno Antunes, Diogo Sousa Influence of Heat Pipe Operating Temperature on Exhaust Heat Thermoelectric Generation SAE International Journal of Passenger Cars - Mechanical Systems 6(2):2013 652-664por
dc.identifier.issn1946-3995por
dc.identifier.urihttps://hdl.handle.net/1822/26582-
dc.description.abstractIncreasingly stringent targets on energy efficiency and emissions, as well as growing vehicle electrification are making attractive the electric recovery of the energy normally wasted through the tailpipe of Internal Combustion Engines. Recent developments in thermoelectrics (TE) may soon make them a viable solution for such applications. This team has been exploring the potential of using TE modules in combination with variable conductance heat pipes for transferring the exhaust heat to the generator with very low thermal resistance and at a constant, prescribed temperature. This passive temperature control eliminates the need for by-pass systems in the event of temperature overshoots. The operating temperature of a generator should be as high as possible in order to maximize the Seebeck effect. However, currently available modules are temperature limited. Moreover, the higher the HP temperature the less the usable thermal power at the exhaust will be (heat can only be transferred to from a hotter to a colder body). The present work assesses both theoretically and experimentally the influence of the HP temperature in the electric output of a thermoelectric generator. A small diesel engine and a generator were tested and it was found that a high HP operating temperature is only limitative for performance in the cases where low exhaust temperature and low engine power are present. In those cases it is possible to estimate an optimal HP temperature in order to maximize power output. The combined use of Seebeck modules and heat pipes was found to be highly advantageous in various ways.por
dc.description.sponsorshipFundação para a Ciência e a Tecnologia (FCT), FEDER e POFC Competepor
dc.description.sponsorshipMIT Portugal EDAM, Project MOBI-MPPpor
dc.language.isoengpor
dc.publisherSAE Internationalpor
dc.rightsopenAccesspor
dc.subjectWaste heat recoverypor
dc.subjectThermoelectricspor
dc.subjectHeat pipespor
dc.subjectExhaust heat recoverypor
dc.titleInfluence of heat pipe operating temperature on exhaust heat thermoelectric generationpor
dc.typearticlepor
dc.peerreviewedyespor
dc.relation.publisherversionhttp://saepcmech.saejournals.org/content/6/2/652.shortpor
sdum.publicationstatuspublishedpor
oaire.citationStartPage652por
oaire.citationEndPage664por
oaire.citationIssue2por
oaire.citationTitleSAE International Journal of Passenger Cars - Mechanical Systemspor
oaire.citationVolume6por
dc.identifier.doi10.4271/2013-01-0559-
dc.subject.wosScience & Technologypor
sdum.journalSAE International Journal of Passenger Cars: Mechanical Systemspor
Aparece nas coleções:CAlg - Artigos em revistas internacionais / Papers in international journals
CT2M - Artigos em revistas de circulação internacional com arbitragem científica

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
2013-01-0559_final_version_with_ref.pdfMain Document1,82 MBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID