Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/22004

Registo completo
Campo DCValorIdioma
dc.contributor.authorMoreira, Susana Maria Trindade-
dc.contributor.authorOliveira, Daniel V.-
dc.contributor.authorRamos, Luís F.-
dc.contributor.authorFernandes, Raquel-
dc.contributor.authorGuerreiro, João-
dc.contributor.authorLourenço, Paulo B.-
dc.date.accessioned2012-12-21T15:55:43Z-
dc.date.available2012-12-21T15:55:43Z-
dc.date.issued2012-09-
dc.identifier.urihttps://hdl.handle.net/1822/22004-
dc.description.abstractThe global structural performance of masonry buildings, under earthquake loading, is affected by the efficiency of wall-to-floor connections, since they assure the continuity of the energy path and prevent the occurrence of most of the local collapse mechanisms. In fact, out-of-plane behaviour of masonry walls observed in recent seismic events showed the critical importance of proper connections in historical buildings. A review of current literature yields little in terms of experimental and numerical data on the subject. Thus, there is an urgent need to study the behaviour of these connections. The present paper presents a series of tests carried out to characterize the wall-to-floor connections. Different specimens were constructed in laboratory to represent connections found in ‘Gaioleiro’ and Late ‘Pombalino’ buildings in downtown Lisbon. Pull-out tests of wall-to-floor connections were carried out on unstrengthened and strengthened specimens in order to study failure modes, maximum pullout forces, and corresponding displacements. These parameters allow better understanding of this type of connection and also the development of design recommendations for the strengthening.por
dc.language.isoengpor
dc.publisherSociedade Portuguesa de Engenharia Sísmica (SPES)por
dc.rightsopenAccesspor
dc.subjectWall-to-floor connectionspor
dc.subjectPull-out testpor
dc.subjectFailure modespor
dc.subject‘Pombalino’ and ‘Gaioleiro’por
dc.titleExperimental study on the seismic behavior of masonry wall-to-floor connectionspor
dc.typeconferencePaper-
dc.peerreviewedyespor
sdum.publicationstatuspublishedpor
oaire.citationConferenceDate24 - 28 Sept. 2012por
sdum.event.typeconferencepor
oaire.citationStartPage1por
oaire.citationEndPage10por
oaire.citationConferencePlaceLisbon, Portugalpor
oaire.citationTitle15th World Conference on Earthquake Engineeringpor
sdum.conferencePublication15th World Conference on Earthquake Engineeringpor
Aparece nas coleções:ISISE - Comunicações a Conferências Internacionais

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
2012_Experimental study on the seismic behavior of masonry wall-to-floor connections.pdfArtigo474,78 kBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID