Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/17171

TítuloPosterior chamber collagen copolymer phakic intraocular lenses to correct myopia : five-year follow-up
Autor(es)Alfonso, José F.
Baamonde, Begoña
Fernández-Vega, Luis
Fernandes, Paulo Rodrigues
González-Méijome, José Manuel
Montés-Micó, Robert
Data2011
EditoraElsevier 1
RevistaJournal of Cataract & Refractive Surgery
Resumo(s)PURPOSE: To evaluate the long-term safety and efficacy of posterior chamber collagen copolymer phakic intraocular lens (pIOL) implantation to correct myopia. SETTING: Fern!andez-Vega Ophthalmological Institute, Oviedo, Spain. DESIGN: Cohort study. METHODS: Uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refraction, pIOL vault, endothelial cell loss, and adverse events were evaluated for 5 years after implantation of the Visian Implantable Collamer Lens pIOL for moderate to high myopia. RESULTS: The mean spherical equivalent (188 eyes) decreased from !11.17 diopters (D)G 3.40 (SD) preoperatively to!0.88G0.72 D 5 years postoperatively. The mean change in refraction from 1 month to 5 years was !0.65G0.65 D. The mean UDVA and CDVA (Snellen decimal) were 0.69G 0.26 and 0.83 G 0.15, respectively. The mean safety and efficacy indices were 1.27 G 0.33 and 0.89 G 0.35, respectively. No eye lost more than 2 lines of visual acuity; 70% achieved 0.80 or better CDVA. Three eyes (1.6%) developed late anterior subcapsular cataract that was clinically significant in 1 case, leading to pIOL removal and phacoemulsification. Of the 3 eyes (1.6%) with a mild transient increase in intraocular pressure (up to 27 mm Hg), none required a second surgical procedure or prolonged topical medication. The total endothelial cell loss (considered cumulatively at consecutive intervals through 5 years) was 7.7%. There was a tendency toward decreased pIOL vault decrease over time. No vision-threatening complications occurred. CONCLUSION: Implantation of the collagen copolymer pIOL for moderate to high myopia was safe and effective and provided long-term predictable, stable refractive results.
TipoArtigo
URIhttps://hdl.handle.net/1822/17171
DOI10.1016/j.jcrs.2010.11.040
ISSN0886-3350
Versão da editorahttp://www.sciencedirect.com/
Arbitragem científicayes
AcessoAcesso aberto
Aparece nas coleções:ICVS - Artigos em revistas internacionais / Papers in international journals
CDF - OCV - Artigos/Papers (with refereeing)

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
5.5.54. ALFONSO_11_JCRS_ (5Year Follow-up ICL).pdf619,74 kBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID