dc.contributor.author | Alfonso, José F. | - |
dc.contributor.author | Baamonde, Begoña | - |
dc.contributor.author | Fernández-Vega, Luis | - |
dc.contributor.author | Fernandes, Paulo Rodrigues | - |
dc.contributor.author | González-Méijome, José Manuel | - |
dc.contributor.author | Montés-Micó, Robert | - |
dc.date.accessioned | 2012-02-16T14:08:10Z | - |
dc.date.available | 2012-02-16T14:08:10Z | - |
dc.date.issued | 2011 | - |
dc.identifier.issn | 0886-3350 | - |
dc.identifier.uri | https://hdl.handle.net/1822/17171 | - |
dc.description.abstract | PURPOSE: To evaluate the long-term safety and efficacy of posterior chamber collagen copolymer phakic intraocular lens (pIOL) implantation to correct myopia. SETTING: Fern!andez-Vega Ophthalmological Institute, Oviedo, Spain. DESIGN: Cohort study. METHODS: Uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refraction, pIOL vault, endothelial cell loss, and adverse events were evaluated for 5 years after implantation of the Visian Implantable Collamer Lens pIOL for moderate to high myopia. RESULTS: The mean spherical equivalent (188 eyes) decreased from !11.17 diopters (D)G 3.40 (SD) preoperatively to!0.88G0.72 D 5 years postoperatively. The mean change in refraction from 1 month to 5 years was !0.65G0.65 D. The mean UDVA and CDVA (Snellen decimal) were 0.69G 0.26 and 0.83 G 0.15, respectively. The mean safety and efficacy indices were 1.27 G 0.33 and 0.89 G 0.35, respectively. No eye lost more than 2 lines of visual acuity; 70% achieved 0.80 or better CDVA. Three eyes (1.6%) developed late anterior subcapsular cataract that was clinically significant in 1 case, leading to pIOL removal and phacoemulsification. Of the 3 eyes (1.6%) with a mild transient increase in intraocular pressure (up to 27 mm Hg), none required a second surgical procedure or prolonged topical medication. The total endothelial cell loss (considered cumulatively at consecutive intervals through 5 years) was 7.7%. There was a tendency toward decreased pIOL vault decrease over time. No vision-threatening complications occurred. CONCLUSION: Implantation of the collagen copolymer pIOL for moderate to high myopia was safe and effective and provided long-term predictable, stable refractive results. | por |
dc.description.sponsorship | Supported in part by grants from the Ministerio de Ciencia e Innovacion Research (SAF2008-01114 and SAF2009-13342) (Dr. Montes-Mico) and Fundacao para a Ciencia e Tecnologia of Portugal (FCT-SFRH-BD-34303-2007) (Dr. Fernandes). | por |
dc.language.iso | eng | por |
dc.publisher | Elsevier 1 | por |
dc.rights | openAccess | por |
dc.title | Posterior chamber collagen copolymer phakic intraocular lenses to correct myopia : five-year follow-up | por |
dc.type | article | - |
dc.peerreviewed | yes | por |
dc.relation.publisherversion | http://www.sciencedirect.com/ | por |
sdum.publicationstatus | published | por |
oaire.citationStartPage | 873 | por |
oaire.citationEndPage | 880 | por |
oaire.citationIssue | 5 | por |
oaire.citationTitle | Journal of Cataract & Refractive Surgery | por |
oaire.citationVolume | 37 | por |
dc.date.updated | 2012-01-04T14:40:37Z | - |
dc.identifier.doi | 10.1016/j.jcrs.2010.11.040 | por |
dc.identifier.pmid | 21511154 | por |
dc.subject.wos | Science & Technology | por |
sdum.journal | Journal of Cataract & Refractive Surgery | por |
Aparece nas coleções: | ICVS - Artigos em revistas internacionais / Papers in international journals CDF - OCV - Artigos/Papers (with refereeing) |
Ficheiros deste registo:
Ficheiro | Descrição | Tamanho | Formato | |
---|---|---|---|---|
5.5.54. ALFONSO_11_JCRS_ (5Year Follow-up ICL).pdf | 619,74 kB | Adobe PDF | Ver/Abrir |