CitaçãoTeixeira, I. M., Esteves, D. B., Rodrigues, N. J., Martins, L. A., Teixeira, J. C., Ferreira, A. C., & Teixeira, S. F. (2022, May). Thermal Comfort Assessment of a Small House in Portugal Using EnergyPlus and Ansys Fluent. In International Conference on Electronic Engineering and Renewable Energy Systems (pp. 917-924). Singapore: Springer Nature Singapore.
Resumo(s)According to the European Union Directive 2018/844, almost 50% of the final energy consumption is used in heating and cooling processes, whereas, of these, 80% are used in the buildings. Thus, to accomplish the proposed energy and climate objectives for 2050, priority has to be given to energy efficiency as well as the deployment of renewable energies in buildings. Most thermal modeling of buildings is carried out through computational dynamic simulation programs. The main objective of this paper is to compare the thermal analyses performed by two programs, EnergyPlus and Ansys Fluent. For this, the model of a simplified building was created, with its thermal surroundings, envelope characteristics, and technical systems. In the model, the insulation of the building was not considered, in order to better compare both software under study. The objective is to verify if two different philosophy software have similar results and validate them. Finally, the temperature and PMV results obtained from EnergyPlus are compared with the results of Ansys Fluent. There was a small deviation for both software, with a PMV value of -1.10 for the EnergyPlus and for -1.12 Fluent. The PMV distribution was compared with K–S test that showed no significant statistical differences.
TipoArtigo em ata de conferência
URIhttps://hdl.handle.net/1822/90580
ISBN978-981-19-6222-6
e-ISBN978-981-19-6223-3
DOI10.1007/978-981-19-6223-3_94
ISSN1876-1100
Versão da editorahttps://link.springer.com/chapter/10.1007/978-981-19-6223-3_94#citeas
Arbitragem científicayes
AcessoAcesso restrito autor
Aparece nas coleções:MEtRICs - Artigos em livros de atas/Papers in proceedings

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
ICEERE2022_ANSYS_ENERGYPLUS.pdf
Acesso restrito!
126,35 kBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID