Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/89068

TítuloCyclic quasi-static testing of a half-scale, two-story unreinforced masonry building with structural irregularity
Autor(es)Asikoglu, Abide
Vasconcelos, Graça
Lourenço, Paulo B.
Palavras-chaveQuasi-static test
Cyclic
Unreinforced masonry
Structural irregularities
Experimental pushover
Data2022
Resumo(s)Pushover analysis is a straightforward tool to be applied in engineering practice to validate a numerical method, or to use performance-based design/assessment methods. Yet, a limited number of the experimental campaign, which studies the building response in a quasi-static regimen, exists. In the present study, cyclic quasi-static testing of a half-scale two-story unreinforced masonry building with structural irregularity has been performed at the Laboratory of the Structures at the University of Minho. A typical building typology has been selected and the structural irregularity is introduced by a setback in one corner of the building plan. The loading has been applied as unidirectional at the centre of mass to observe the torsional effects due to irregularity. In the present paper, the testing procedure, and the main experimental findings are presented and discussed.
TipoArtigo em ata de conferência
URIhttps://hdl.handle.net/1822/89068
ISBN978-972-49-2323-9
Arbitragem científicayes
AcessoAcesso aberto
Aparece nas coleções:ISISE - Comunicações a Conferências Nacionais

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
JPEE2022_Masonry Building.pdf2,78 MBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut