Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/81826

Registo completo
Campo DCValorIdioma
dc.contributor.authorSánchez Trancón, Angelpor
dc.contributor.authorCerpa Manito, Santiagopor
dc.contributor.authorTorrado Sierra, Oscarpor
dc.contributor.authorBaptista, António M. G.por
dc.contributor.authorSerra, Pedro Miguelpor
dc.date.accessioned2023-01-13T11:38:08Z-
dc.date.available2023-01-13T11:38:08Z-
dc.date.issued2022-11-15-
dc.identifier.citationSánchez Trancón, A., Cerpa Manito, S., Torrado Sierra, O. et al. Vault differences in eyes implanted with spherical and toric implantable collamer lenses: an inter-eye analysis. BMC Ophthalmol 22, 435 (2022). https://doi.org/10.1186/s12886-022-02653-ypor
dc.identifier.urihttps://hdl.handle.net/1822/81826-
dc.description.abstractPurpose To determine the influence of implantable collamer lenses (ICL) geometry, i.e. spherical and toric on the vault, and report the refractive and visual outcomes of patients bilaterally implanted with the two ICL geometries. Methods: This retrospective case series analysed 41 patients implanted with a spherical ICL (sICL) in one eye and an equal sized toric ICL (tICL) in the fellow eye. The anatomical and ICL-related parameters were assessed using anterior-segment optical coherence tomography (AS-OCT Visante, Zeiss Meditec AG) and optical tomography (Pentacam, OCULUS). The influence of the anatomical and ICL-related parameters on the vault was determined using generalised estimating equations (GEE) to incorporate inter-eye correlations. Results: Postoperative spherical equivalent was within ± 0.50D in 66% and 83% of the eyes, respectively implanted with sICL and tICL. The efficacy index in the sICL group was 1.06 and 1.14 in the tICL group. The mean inter-eye vault difference was -1.46 µm, anatomical and ICL-related parameters showed similar associations with the vault for sICL and tICL. The GEE identified the ICL size minus the anterior chamber width, the ICL spherical power and ICL central thickness as significant factors influencing the vault. Conclusions: Spherical and toric ICL showed good efficacy for the correction of myopia and astigmatism. Patients implanted bilaterally with sICL and tICL tend to present similar vaults. The vault produced by both types of ICL was mainly regulated by the oversizing of the ICL. This suggests that the ICL geometry (spherical vs toric) is a factor with limited influence on the vault, thus the sizing method of a sICL and tICL should be similar.por
dc.language.isoengpor
dc.publisherBMCpor
dc.rightsopenAccesspor
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/por
dc.subjectHumanspor
dc.subjectLens Implantation, Intraocularpor
dc.subjectRetrospective Studiespor
dc.subjectVisual Acuitypor
dc.subjectAnterior Chamberpor
dc.subjectPhakic Intraocular Lensespor
dc.subjectImplantable collamer lensespor
dc.subjectToric implantable collamer lensespor
dc.subjectVaultpor
dc.subjectEfficacy indexpor
dc.subjectGeneralised estimating equationspor
dc.titleVault differences in eyes implanted with spherical and toric implantable collamer lenses: an inter-eye analysispor
dc.typearticlepor
dc.peerreviewedyespor
dc.relation.publisherversionhttps://bmcophthalmol.biomedcentral.com/articles/10.1186/s12886-022-02653-ypor
oaire.citationIssue1por
oaire.citationVolume22por
dc.identifier.eissn1471-2415por
dc.identifier.doi10.1186/s12886-022-02653-ypor
dc.identifier.pmid36376808por
dc.subject.fosCiências Médicas::Medicina Clínicapor
dc.subject.wosScience & Technologypor
sdum.journalBMC Ophthalmologypor
oaire.versionVoRpor
dc.identifier.articlenumber435por
Aparece nas coleções:ASSESSMENT AND ENHANCING VISUAL PERFORMANCE (2018 - ...)

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
s12886-022-02653-y.pdf3,01 MBAdobe PDFVer/Abrir

Este trabalho está licenciado sob uma Licença Creative Commons Creative Commons

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID