Utilize este identificador para referenciar este registo:
https://hdl.handle.net/1822/81826
Registo completo
Campo DC | Valor | Idioma |
---|---|---|
dc.contributor.author | Sánchez Trancón, Angel | por |
dc.contributor.author | Cerpa Manito, Santiago | por |
dc.contributor.author | Torrado Sierra, Oscar | por |
dc.contributor.author | Baptista, António M. G. | por |
dc.contributor.author | Serra, Pedro Miguel | por |
dc.date.accessioned | 2023-01-13T11:38:08Z | - |
dc.date.available | 2023-01-13T11:38:08Z | - |
dc.date.issued | 2022-11-15 | - |
dc.identifier.citation | Sánchez Trancón, A., Cerpa Manito, S., Torrado Sierra, O. et al. Vault differences in eyes implanted with spherical and toric implantable collamer lenses: an inter-eye analysis. BMC Ophthalmol 22, 435 (2022). https://doi.org/10.1186/s12886-022-02653-y | por |
dc.identifier.uri | https://hdl.handle.net/1822/81826 | - |
dc.description.abstract | Purpose To determine the influence of implantable collamer lenses (ICL) geometry, i.e. spherical and toric on the vault, and report the refractive and visual outcomes of patients bilaterally implanted with the two ICL geometries. Methods: This retrospective case series analysed 41 patients implanted with a spherical ICL (sICL) in one eye and an equal sized toric ICL (tICL) in the fellow eye. The anatomical and ICL-related parameters were assessed using anterior-segment optical coherence tomography (AS-OCT Visante, Zeiss Meditec AG) and optical tomography (Pentacam, OCULUS). The influence of the anatomical and ICL-related parameters on the vault was determined using generalised estimating equations (GEE) to incorporate inter-eye correlations. Results: Postoperative spherical equivalent was within ± 0.50D in 66% and 83% of the eyes, respectively implanted with sICL and tICL. The efficacy index in the sICL group was 1.06 and 1.14 in the tICL group. The mean inter-eye vault difference was -1.46 µm, anatomical and ICL-related parameters showed similar associations with the vault for sICL and tICL. The GEE identified the ICL size minus the anterior chamber width, the ICL spherical power and ICL central thickness as significant factors influencing the vault. Conclusions: Spherical and toric ICL showed good efficacy for the correction of myopia and astigmatism. Patients implanted bilaterally with sICL and tICL tend to present similar vaults. The vault produced by both types of ICL was mainly regulated by the oversizing of the ICL. This suggests that the ICL geometry (spherical vs toric) is a factor with limited influence on the vault, thus the sizing method of a sICL and tICL should be similar. | por |
dc.language.iso | eng | por |
dc.publisher | BMC | por |
dc.rights | openAccess | por |
dc.rights.uri | http://creativecommons.org/licenses/by/4.0/ | por |
dc.subject | Humans | por |
dc.subject | Lens Implantation, Intraocular | por |
dc.subject | Retrospective Studies | por |
dc.subject | Visual Acuity | por |
dc.subject | Anterior Chamber | por |
dc.subject | Phakic Intraocular Lenses | por |
dc.subject | Implantable collamer lenses | por |
dc.subject | Toric implantable collamer lenses | por |
dc.subject | Vault | por |
dc.subject | Efficacy index | por |
dc.subject | Generalised estimating equations | por |
dc.title | Vault differences in eyes implanted with spherical and toric implantable collamer lenses: an inter-eye analysis | por |
dc.type | article | por |
dc.peerreviewed | yes | por |
dc.relation.publisherversion | https://bmcophthalmol.biomedcentral.com/articles/10.1186/s12886-022-02653-y | por |
oaire.citationIssue | 1 | por |
oaire.citationVolume | 22 | por |
dc.identifier.eissn | 1471-2415 | por |
dc.identifier.doi | 10.1186/s12886-022-02653-y | por |
dc.identifier.pmid | 36376808 | por |
dc.subject.fos | Ciências Médicas::Medicina Clínica | por |
dc.subject.wos | Science & Technology | por |
sdum.journal | BMC Ophthalmology | por |
oaire.version | VoR | por |
dc.identifier.articlenumber | 435 | por |
Aparece nas coleções: | ASSESSMENT AND ENHANCING VISUAL PERFORMANCE (2018 - ...) |
Ficheiros deste registo:
Ficheiro | Descrição | Tamanho | Formato | |
---|---|---|---|---|
s12886-022-02653-y.pdf | 3,01 MB | Adobe PDF | Ver/Abrir |
Este trabalho está licenciado sob uma Licença Creative Commons