Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/78641

Registo completo
Campo DCValorIdioma
dc.contributor.authorBetti, Michelepor
dc.contributor.authorGalano, Lucianopor
dc.contributor.authorLourenço, Paulo B.por
dc.date.accessioned2022-07-06T15:43:33Z-
dc.date.issued2021-05-
dc.identifier.citationBetti, M., Galano, L., & Lourenço, P. B. (2021, May). Territorial seismic risk assessment of a sample of 13 masonry churches in Tuscany (Italy) through simplified indexes. Engineering Structures. Elsevier BV. http://doi.org/10.1016/j.engstruct.2020.111479-
dc.identifier.issn0141-0296por
dc.identifier.urihttps://hdl.handle.net/1822/78641-
dc.description.abstractAmong heritage buildings, masonry churches are complex structures often characterized by an open plan layout with slender perimeter walls. Their vulnerability to earthquakes is frequently increased by the absence of adequate connections between the various parts of the structural complex, together with the presence of thrusting horizontal elements such as masonry vaults and timber roofs. In this paper, the vulnerability and the seismic risk of thirteen masonry churches located in Tuscany (Italy) have been analysed with simplified methods to establish a first screening of the risk of this heritage typology. The methods are that proposed by Louren?o and Roque in 2006 and the so-called first level of analysis (LA-1), introduced by the Italian code. For one of these churches, the Basilica of San Francesco in Arezzo, the analyses of second (LA-2) and third (LA-3) level have been also performed according to the same code. The results highlight the contribution of the simplified approaches to establish a first selection of the priorities for subsequent investigations and, if needed, proper interventions. Approximately one-half of the churches composing the sample have the normalized simplified indexes lower than one, indicating the need of further investigations. For the Basilica of San Francesco the results of LA-2 level of analysis confirm the conclusions obtained with the more simplified procedures, while a criticism is highlighted with the LA-3 approach when the N2 method is adopted in combination with a pushover methodology of analysis.por
dc.language.isoengpor
dc.publisherElsevier 1por
dc.rightsrestrictedAccesspor
dc.subjectCultural heritagepor
dc.subjectMasonry churchespor
dc.subjectSeismic vulnerabilitypor
dc.subjectSimplified indexespor
dc.titleTerritorial seismic risk assessment of a sample of 13 masonry churches in Tuscany (Italy) through simplified indexespor
dc.typearticle-
dc.peerreviewedyespor
dc.relation.publisherversionhttps://www.sciencedirect.com/science/article/pii/S0141029620340803por
oaire.citationStartPage1por
oaire.citationEndPage16por
oaire.citationVolume235por
dc.date.updated2022-06-30T16:13:09Z-
dc.identifier.doi10.1016/j.engstruct.2020.111479por
dc.date.embargo10000-01-01-
dc.subject.wosScience & Technology-
sdum.export.identifier12274-
sdum.journalEngineering Structurespor
dc.identifier.articlenumber111479por
Aparece nas coleções:ISISE - Artigos em Revistas Internacionais

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
2021_ES_235_Territorialseismicriskassessmentofasampleof13masonrychurchesinTuscanyItalythroughsimplifiedindexes.pdf
Acesso restrito!
9,45 MBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID