Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/66255

Registo completo
Campo DCValorIdioma
dc.contributor.authorBranco, Jorge M.por
dc.contributor.authorMatos, Filipe T.por
dc.contributor.authorLourenço, Paulo B.por
dc.contributor.authorDemschner, Thomaspor
dc.contributor.authorRocha, Patríciopor
dc.date.accessioned2020-08-04T09:43:23Z-
dc.date.available2020-08-04T09:43:23Z-
dc.date.issued2019-
dc.identifier.isbn9783857481635por
dc.identifier.urihttps://hdl.handle.net/1822/66255-
dc.description.abstractA two storey full-scale model of a CLT house, of 4.5 m x 9.1 m in-plane, with a height of 5.04 m, was tested under quasi-static monotonic (pushover). The main objectives were to investigate the 3-D system performance of a CLT structure subjected to lateral loads in terms of lateral strength and deformability capacity, global behaviour of the structure, frequency response of the structure, performance of connectors (mainly hold-downs and angle-brackets) and connections between CLT panels. Lateral loads have been applied on the storeys inducing torsion to the building. Loading procedure, number and disposition of connectors varied between tests. With this campaign it is intended to obtain results on: i) load-deformation response of a 3-D CLT structure subjected to lateral loads; ii) global response of the structure, focusing on the performance of CLT slabs subjected to in-plane loads, performance of parallel and perpendicular walls, and response of the structure near openings; iii) failure mechanisms and on the performance of connections between CLT panels and connectors. The outcomes of the full-scale CLT house tests will be used for further analytical and numerical analyses to help implement the new generation of Eurocode 8.por
dc.description.sponsorship- (undefined)por
dc.language.isoengpor
dc.publisherInternational Association for Bridge and Structural Engineering (IABSE)por
dc.rightsopenAccesspor
dc.subjectCross Laminated Timberpor
dc.subjectEurocode 8por
dc.subjectFull-scale testspor
dc.subjectSeismic designpor
dc.titleLateral tests on a two-story CLT housepor
dc.typeconferencePaperpor
dc.peerreviewedyespor
oaire.citationStartPage969por
oaire.citationEndPage977por
dc.date.updated2020-08-04T09:34:11Z-
sdum.export.identifier5780-
sdum.conferencePublicationIABSE Symposium, Guimaraes 2019: Towards a Resilient Built Environment Risk and Asset Management - Reportpor
Aparece nas coleções:ISISE - Comunicações a Conferências Internacionais

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
LATERAL TESTS ON A TWO-STORY CLT HOUSE - IABSE_Guimaraes2019.pdf2,1 MBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID