Utilize este identificador para referenciar este registo:
https://hdl.handle.net/1822/61286
Título: | An impedimetric molecularly-imprinted biosensor for Interleukin-1 determination, prepared by in-situ electropolymerization on carbon screen-printed electrodes |
Autor(es): | Cardoso, Rita Sá, Maria Helena Sales, M. G. F. |
Palavras-chave: | Interleukin-1ß (IL-1ß) Molecularly imprinted polymer (MIP) Biosensor Electropolymerization Screen-printed carbon electrodes (SPCEs) Electrochemical impedance spectroscopy (EIS) Interleukin-1β (IL-1β) |
Data: | Dez-2019 |
Editora: | Elsevier 1 |
Revista: | Bioelectrochemistry |
Citação: | Cardoso, Rita; Sá, Maria Helena; Sales, M. G. F., An impedimetric molecularly-imprinted biosensor for Interleukin-1 determination, prepared by in-situ electropolymerization on carbon screen-printed electrodes. Bioelectrochemistry, 130(107287), 2019 |
Resumo(s): | This work reports the first electrochemical molecularly imprinted polymer (MIP) sensor for Interleukin-1beta (IL-1) detection, based on modified commercial screen-printed carbon electrode (SPCE) was successfully demonstrated. For this purpose, the carbon support was modified with a PEDOT/4-aminothiophenol layer prior to the MIP film to enhance sensitivity and signal stability. The MIP layer was constructed on top of this by electropolymerization of Eriochrome black T (EBT) in the presence of IL-1. The several steps of the biosensor assembly was followed by Raman spectroscopy and electroanalytical techniques. Using electrochemical impedance spectroscopy (EIS), a linear response in the range of 60 pM to 600nM, with a LOD of 1.5 pM with (S/N=3) was obtained in neutral PBS. Selectivity tests of the MIP biosensor made in spiked synthetic serum samples as well as against other structurally related (Myoglobin, of similar shape and size) or competing compounds (Immunoglobulin G, also present in the human serum) confirmed the good selectivity of the biosensor. Overall, the biosensor described herein has the potential to provide a simple and quick way for on-site screening of IL-1, with low sample/reagent consumption and enabling direct serum analysis, which constitutes a valuable alternative to other conventional methods. |
Tipo: | Artigo |
URI: | https://hdl.handle.net/1822/61286 |
DOI: | 10.1016/j.bioelechem.2019.04.017 |
ISSN: | 1567-5394 |
Versão da editora: | http://www.journals.elsevier.com/bioelectrochemistry/ |
Arbitragem científica: | yes |
Acesso: | Acesso aberto |
Aparece nas coleções: | CEB - Publicações em Revistas/Séries Internacionais / Publications in International Journals/Series |
Ficheiros deste registo:
Ficheiro | Descrição | Tamanho | Formato | |
---|---|---|---|---|
document_51694_1.pdf | 1,5 MB | Adobe PDF | Ver/Abrir |