Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/5638

Registo completo
Campo DCValorIdioma
dc.contributor.authorMinas, Graça-
dc.contributor.authorGraaf, G. de-
dc.contributor.authorWolffenbuttel, R. F.-
dc.contributor.authorCorreia, J. H.-
dc.date.accessioned2006-10-03T14:29:31Z-
dc.date.available2006-10-03T14:29:31Z-
dc.date.issued2006-
dc.date.submitted2005-03-11-
dc.identifier.citation"IEEE sensors journal". ISSN 1530-437X. 6:4 (Aug.2006) 1003-1009.eng
dc.identifier.issn1530-437Xeng
dc.identifier.urihttps://hdl.handle.net/1822/5638-
dc.description.abstractThis paper presents a multichip module microsystem for biological fluid analysis. It is composed of three parts, namely 1) CMOS silicon optical detection microsystem, which includes a photodetector and a light-to-frequency converter for readout; 2) dielectric thin-film-based optical filter on top of the photodetector fabricated using IC-compatible postprocessing; and 3) glass die on top containing the microchannels fabricated using SU-8 techniques. The application is in low-cost quantitative measurement of the concentration of biomolecules in biological fluids. Its operation is based on optical absorption in the part of the visible spectrum that is defined by the specific biomolecule. Signals proportional to the intensity of the light transmitted through the biological fluid are available at the output in the form of bit streams, which allows simple computer interfacing. The quantitative measurement of the total protein in urine is successfully demonstrated. The photodiode responsivity is 224 mA/W with a full-width at half-maximum of 10 nm at λ = 600 nm. The optical system sensitivity is 1 kHz/W m−2 at λ = 670 nm.eng
dc.description.sponsorshipFundação para a Ciência e a Tecnologia (FCT)(SFRH/BD/1281/2000. Fundo Europeu para o Desenvolvimento Regional - POCTI/33747/ESE/1999.por
dc.language.isoengeng
dc.publisherIEEEeng
dc.rightsrestrictedAccesseng
dc.subjectBiomolecule analysiseng
dc.subjectMultichip module (MCM)eng
dc.subjectOptical absorptioneng
dc.subjectSU-8 techniqueseng
dc.titleAn MCM-based microsystem for colorimetric detection of biomolecules in biological fluidseng
dc.typearticlepor
dc.peerreviewedyeseng
dc.relation.publisherversionhttp://ieeexplore.ieee.org/xpl/RecentIssue.jsp?punumber=7361eng
sdum.number4eng
sdum.pagination1003-1009eng
sdum.publicationstatuspublishedeng
sdum.volume6eng
oaire.citationStartPage1003por
oaire.citationEndPage1009por
oaire.citationIssue4por
oaire.citationVolume6por
dc.identifier.doi10.1109/JSEN.2006.877992por
dc.subject.wosScience & Technologypor
sdum.journalIEEE sensors journalpor
Aparece nas coleções:DEI - Artigos em revistas internacionais

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
IEEE sensors Journal V6 N4 2006 p1003_1009.pdf
Acesso restrito!
Documento principal762,25 kBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID