Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/53438

TítuloEnergy and exergy analysis of a biomass power plant
Autor(es)Silva, João Pedro Vasconcelos
Teixeira, S. F. C. F.
Preziati, Simone
Teixeira, J. Carlos
Palavras-chaveEnergy
Exergy
Biomass
Thermal power plant
Data2016
EditoraAmerican Society of Mechanical Engineers (ASME)
CitaçãoSilva, J; Teixeira, SFC; Preziati, S and Teixeira, JCF; (2016). Energy and Exergy Analysis of a Biomass Power Plant. In ASME (Ed.), Volume 6B: Energy, Paper No. IMECE2016-66899, pp. V06BT08A026. Phoenix, AZ, USA: ASME. http://doi: 10.1115/IMECE2016-66899
Resumo(s)The fulfilment of energy targets regarding the use of renewable energy has been a strong incentive to the development of dedicated power plants using biomass. Because these facilities operate with low value residues, this orientation has also received a strong incentive by the quest to reduce the amount of fuel in the woods and lowering the risk of fire. This issue is a major problem in dry climates. Although the number of plants planned for Portugal was very large, the actual number of units in operation is small. The first plant to enter production in Portugal was the thermal power plant of Mortágua. In this paper the energy and exergy analysis in this plant is presented. The objective of this work is to develop an analysis for the energy conversion in the plant. This is based on parameters that were retrieved during its normal operation and include: biomass and air flow rate, temperature measurements of the flue gases throughout the facility including the economizer, the two superheaters and flue gas composition. The elemental analysis of the biomass resulting from a blend of various sources was measured in addition to its moisture (ranging between 20 and 45% depending on the sources). The analysis was carried out for a fuel batch with a moisture of 35%. The plant was operated at three loads (full load, 80% and 65% load) and from the energy/mass balances the overall efficiency was calculated to be approximately 26%. The data were also used to perform a second law analysis of the plant which enables the calculation of the exergy destruction in the various components of the facility, including the external irreversibility. It was observed that the combustion chamber is the prime contributor to the overall loss of efficiency. The exergy efficiency was found approximately 22%.
TipoArtigo em ata de conferência
URIhttps://hdl.handle.net/1822/53438
ISBN9780791850596
DOI10.1115/IMECE2016-66899
Arbitragem científicayes
AcessoAcesso restrito UMinho
Aparece nas coleções:CAlg - Artigos em livros de atas/Papers in proceedings
DEM - Publicações em actas de encontros científicos / Papers in conference proceedings

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
IMECE2016_66899_Final.pdf
Acesso restrito!
415,59 kBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID