Utilize este identificador para referenciar este registo:
https://hdl.handle.net/1822/5061
Título: | Static and dynamic structural monitoring of the Santa Maria of Belém church, in Lisbon |
Autor(es): | Ramos, Luís F. Lourenço, Paulo B. |
Palavras-chave: | Masonry structures Non-linear analysis Dynamic modal identification Health monitoring |
Data: | 2005 |
Citação: | SOARES, C.A. Mota [et al.], ed. lit. - “Smart structures and materials : proceedings of II ECCOMAS Thematic Conference on Smart Structures and Materials, Lisbon, Portugal, 2005”. [S.l. : s.n.], 2005. |
Resumo(s): | The paper details two monitoring systems implemented in the main nave of Santa Maria of Belém Church of the Monastery of Jerónimos, in Lisbon. The monitoring systems are being installed to better understand the static and dynamic behavior of the structure, with the purpose of damage detection and the improvement of seismic resistance of the monument. In the paper, preliminary investigations, numerical non-linear analyses and the first dynamic modal identification analyses are described. Also the preliminary works for the monitoring systems are presented, including the points selected for observation, the discussion of the sensors technical characteristics, as well as preliminary inspection and diagnosis. The first results of the dynamic monitoring system are shown and the future developments on the systems are presented, aiming at a full integration of all adopted techniques. |
Tipo: | Artigo em ata de conferência |
URI: | https://hdl.handle.net/1822/5061 |
Arbitragem científica: | yes |
Acesso: | Acesso aberto |
Aparece nas coleções: | CEC-EST - Comunicações a Conferências Internacionais |
Ficheiros deste registo:
Ficheiro | Descrição | Tamanho | Formato | |
---|---|---|---|---|
Ramos-Lourenco-2.pdf | 912,37 kB | Adobe PDF | Ver/Abrir |