Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/48443

Registo completo
Campo DCValorIdioma
dc.contributor.authorHarzalli, Ussamapor
dc.contributor.authorRodrigues, Nunopor
dc.contributor.authorVeloso, Ana C. A.por
dc.contributor.authorDias, Luís G.por
dc.contributor.authorPereira, José A.por
dc.contributor.authorOueslati, Souheibpor
dc.contributor.authorPeres, António M.por
dc.date.accessioned2017-12-19T16:17:03Z-
dc.date.available2017-12-19T16:17:03Z-
dc.date.issued2018-
dc.identifier.citationHarzalli, Ussama; Rodrigues, Nuno; Veloso, Ana C. A.; Dias, Luís G.; Pereira, José A.; Oueslati, Souheib; Peres, António M., A taste sensor device for unmasking admixing of rancid or winey-vinegary olive oil to extra virgin olive oil. Computers and Electronics in Agriculture, 144, 222-231, 2018por
dc.identifier.issn0168-1699por
dc.identifier.urihttps://hdl.handle.net/1822/48443-
dc.description.abstractElectrochemical sensor devices have gathered great attention in food analysis namely for olive oil evaluation. The adulteration of extra-virgin olive oil with lower-grade olive oil is a common worldwide fraudulent practice, which detection is a challenging task. The potentiometric fingerprints recorded by lipid polymeric sensor membranes of an electronic tongue, together with linear discriminant analysis and simulated annealing meta-heuristic algorithm, enabled the detection of extra-virgin olive oil adulterated with olive oil for which an intense sensory defect could be perceived, specifically rancid or winey-vinegary negative sensations. The homemade designed taste device allowed the identification of admixing of extra-virgin olive oil with more than 2.5% or 5% of rancid or winey-vinegary olive oil, respectively. Predictive mean sensitivities of 84±4% or 92±4% and specificities of 79±6% or 93±3% were obtained for rancid or winey-vinegary adulterations, respectively, regarding an internal-validation procedure based on a repeated K-fold cross-validation variant (4 folds×10 repeats, ensuring that the dataset was forty times randomly split into 4 folds, leaving 25% of the data for validation purposes). This performance was satisfactory since, according to the legal physicochemical and sensory analysis, the intentionally adulterated olive oil with percentages of 2.510%, could still be commercialized as virgin olive oil. It could also be concluded that at a 5% significance level, the trained panelists could not distinguish extra-virgin olive oil samples from those adulterated with 2.5% of rancid olive oil or up to 5% of winey-vinegary olive oil. Thus, the electronic tongue proposed in this study can be foreseen as a practical and powerful tool to detect this kind of worldwide common fraudulent practice of high quality olive oil.por
dc.description.sponsorshipThis work was financially supported by Project POCI-01–0145FEDER-006984 – Associate Laboratory LSRE-LCM, Project UID/QUI/ 00616/2013 – CQ-VR, Project UID/BIO/04469/2013 – CEB and strategic project PEst-OE/AGR/UI0690/2014 – CIMO all funded by FEDER - Fundo Europeu de Desenvolvimento Regional through COMPETE2020 - Programa Operacional Competitividade e Internacionalização (POCI) – and by national funds through FCT - Fundação para a Ciência e a Tecnologia, Portugal. Nuno Rodrigues thanks FCT, POPH-QREN and FSE for the Ph.D. Grant (SFRH/BD/104038/2014). Souheib Oueslati is also grateful for the support of the Tunisian Ministry of Agriculture.por
dc.language.isoengpor
dc.publisherElsevier 1por
dc.relationinfo:eu-repo/grantAgreement/FCT/5876/147416/PTpor
dc.relationinfo:eu-repo/grantAgreement/FCT/5876/147337/PTpor
dc.relationinfo:eu-repo/grantAgreement/FCT/5876/135938/PTpor
dc.relationSFRH/BD/104038/2014por
dc.rightsopenAccesspor
dc.subjectElectronic tonguepor
dc.subjectChemometricspor
dc.subjectOlive oilpor
dc.subjectPhysicochemical analysispor
dc.subjectSensory analysispor
dc.subjectAdulteration detectionpor
dc.titleA taste sensor device for unmasking admixing of rancid or winey-vinegary olive oil to extra virgin olive oilpor
dc.typearticle-
dc.peerreviewedyespor
dc.relation.publisherversionhttps://www.journals.elsevier.com/computers-and-electronics-in-agriculturepor
dc.commentsCEB47352por
oaire.citationStartPage222por
oaire.citationEndPage231por
oaire.citationConferencePlaceNetherlands-
oaire.citationVolume144por
dc.date.updated2017-12-19T15:30:33Z-
dc.identifier.doi10.1016/j.compag.2017.12.016por
dc.description.publicationversioninfo:eu-repo/semantics/publishedVersionpor
dc.subject.wosScience & Technologypor
sdum.journalComputers and Electronics in Agriculturepor
Aparece nas coleções:CEB - Publicações em Revistas/Séries Internacionais / Publications in International Journals/Series

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
document_47352_1.pdf555,1 kBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID