Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/2351

Registo completo
Campo DCValorIdioma
dc.contributor.authorMinas, Graça-
dc.contributor.authorRibeiro, J. C.-
dc.contributor.authorGraaf, G. de-
dc.contributor.authorWolffenbuttel, R. F.-
dc.contributor.authorCorreia, J. H.-
dc.date.accessioned2005-06-27T12:41:29Z-
dc.date.available2005-06-27T12:41:29Z-
dc.date.issued2004-
dc.identifier.citationROCHA, D.; SARRO, P. M.; VELLEKOOP, M. J., ed. lit. – “ Proceedings of the IEEE sensors, Vienna, 2004”. Piscataway, NJ : IEEE, 2004. ISBN 0-7803-8692-2. p. 223-226.eng
dc.identifier.isbn0-7803-8692-2-
dc.identifier.issn1930-0395por
dc.identifier.urihttps://hdl.handle.net/1822/2351-
dc.description.abstractThis paper presents a MCM (Multi-Chip-Module) microsystem for biological fluids analysis. It is composed of three parts: (1) a CMOS silicon optical detection microsystem which includes a photodetector and a light-tofrequency converter for readout; (2) a dielectric thin-film based optical filter on top of the photodetector fabricated using IC-compatible post-processing; (3) a glass die on top containing the microchannels fabricated using SU-8 techniques. The application is in the low-cost measurement of concentration of biomolecules in biological fluids, by the optical absorption in a part of the visible spectrum defined by the specific molecule. Signals proportional to the intensity of the light transmitted through the biological fluid are available at the output in the form of bit streams, which allows simple computer interfacing. The quantitative measurement of total protein in urine is successfully demonstrated. The photodiode responsivity is 224 mA/W with a FWHM (Full-Width-Half-Maximum) of 10 nm at = 600 nm. The optical system sensitivity is 1 kHz/Wm-2 at = 670 nm.eng
dc.description.sponsorshipFundação para a Ciência e Tecnologia - SFRH/BD/1281/2000, POCTI/33747/ESE/1999. and FEDER.por
dc.language.isoengeng
dc.publisherIEEEeng
dc.rightsrestrictedAccesseng
dc.subjectMulti-Chip-Moduleeng
dc.subjectBiomolecules analysiseng
dc.subjectSU-8 techniqueseng
dc.subjectOptical absorptioneng
dc.subjectMCM (Multi-Chip-Module)por
dc.titleA MCM-based microsystem for biological fluids analysis by optical absorptioneng
dc.typeconferencePapereng
dc.peerreviewedyeseng
oaire.citationStartPage223por
oaire.citationEndPage226por
oaire.citationVolume1por
dc.subject.wosScience & Technologypor
sdum.journalProceedings of IEEE Sensorspor
sdum.conferencePublicationPROCEEDINGS OF THE IEEE SENSORS 2004, VOLS 1-3por
Aparece nas coleções:DEI - Artigos em atas de congressos internacionais

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
IEEESensors04.pdf
Acesso restrito!
184,35 kBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID