Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/23132

TítuloHydrogels for nucleus replacement: facing a biomechanical challenge
Autor(es)Reitmaier, S.
Wolfram, U.
Ignatius, A.
Wilke, H. - J.
Gloria, A.
Martín-Martínez, José M.
Silva-Correia, Joana
Oliveira, Joaquim M.
Reis, R. L.
Schmidt, H.
Palavras-chaveCompression test
Disc regeneration
Hydrogels
In vitro
In vivo
intervertebral disc
Nucleus replacement
DataOut-2012
EditoraElsevier Science BV
RevistaJournal of the Mechanical Behavior of Biomedical Materials
Resumo(s)Hydrogels are considered promising for disc regeneration strategies. However, it is currently unknown whether the destruction of the natural interface between nucleus and surrounding structures caused by nucleotomy and an inadequate annulus closure diminishes the mechanical competence of the disc. This in vitro study aimed to clarify these mechanisms and to evaluate whether hydrogels are able to restore the biomechanical behaviour of the disc. Nucleus pressure in an ovine intervertebral disc was measured in vivo during day and night and adapted to an in vitro axial compressive diurnal (15min) and night (30min) load. Effects of different defects on disc height and nucleus pressure were subsequently measured in vitro using 30 ovine motion segments. Following cases were considered: intact; annulus incision repaired by suture and glue; annulus incision with removal and re-implantation of nucleus tissue; and two different hydrogels repaired by suture and glue. The intradiscal pressure in vivo was 0.75 MPa during day and 0.5 MPa during night corresponding to an in vitro axial compressive force of 130 and 58 N, respectively. The compression test showed that neither the implantation of hydrogels nor the re-implantation of the natural nucleus, assumed as being the ideal implant, was able to restore the mechanical functionality of an intact disc. Results indicate the importance of the natural anchorage of the nucleus with its surrounding structures and the relevance of an appropriate annulus closure. Therefore, hydrogels that are able to mimic the mechanical behaviour of the native nucleus may fail in restoring the mechanical behaviour of the disc.
TipoArtigo
URIhttps://hdl.handle.net/1822/23132
DOI10.1016/j.jmbbm.2012.05.010
ISSN1751-6161
Arbitragem científicayes
AcessoAcesso aberto
Aparece nas coleções:3B’s - Artigos em revistas/Papers in scientific journals

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
1349168797_Reitmaier et al 2012_JMechBehavBiomedMater.pdf1,55 MBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID