Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/21847

Registo completo
Campo DCValorIdioma
dc.contributor.authorMoreira, Susana Maria Trindade-
dc.contributor.authorRamos, Luís F.-
dc.contributor.authorOliveira, Daniel V.-
dc.contributor.authorFernandes, Raquel P.-
dc.contributor.authorGuerreiro, João-
dc.contributor.authorLourenço, Paulo B.-
dc.date.accessioned2012-12-20T10:34:57Z-
dc.date.available2012-12-20T10:34:57Z-
dc.date.issued2012-10-
dc.identifier.isbn9788371252167por
dc.identifier.urihttps://hdl.handle.net/1822/21847-
dc.description.abstractThe out-of-plane failure mechanisms due to seismic action observed in masonry walls of historical buildings are, in many cases, a direct result of poor connections between structural elements, which are incapable of assuring proper load transmission. Therefore, the need to prevent its occurrence raises critical importance around their unstrengthened and strengthened behaviour. A typical example is the connection between external and internal walls or between walls and floors. The wall-to-half-timbered wall connections are representative of connections existent in ‘Pombalino’ and ‘Gaioleiro’ buildings, constructed during the post-earthquake (1755) reconstruction of downtown Lisbon. In order to better understand the seismic performance of masonry wall-to-half-timbered wall connections and to increase information found in literature, a series of 5 tests were carried out in representative real scale specimens in which injected anchors were installed in an irregular stone masonry wall in order to improve the seismic response of the connection. Monotonic and cyclic pull-out tests were performed on representative connections in order to assess their performance and allow their characterization. Parameters considered include: failure mode, hysteretic curve, strength degradation and total energy. The results contribute to the existent body of knowledge on the topic, by expanding the experimental database. For further development, the experimental data allows the calibration of representative numerical models, enabling parametric studies of material properties and formulation of backbone curves. This data allows idealized behaviour to be established and utilized for the construction of global building models.por
dc.language.isoengpor
dc.publisherJerzy Jasieńkopor
dc.relationinfo:eu-repo/grantAgreement/EC/FP7/244123por
dc.rightsrestrictedAccesspor
dc.subjectWall-to-timber framepor
dc.subjectInjected anchorpor
dc.subjectPull-out testpor
dc.subjectGaioleiropor
dc.subjectWall-to-timber frame connectionpor
dc.titleExperimental seismic behaviour of wall-to-half-timbered wall connectionspor
dc.typeconferencePaper-
dc.peerreviewedyespor
sdum.publicationstatuspublishedpor
oaire.citationConferenceDate15 - 17 out. 2012por
sdum.event.typeconferencepor
oaire.citationStartPage1639por
oaire.citationEndPage1646por
oaire.citationConferencePlaceWroclaw, Polandpor
oaire.citationTitle8th International Conference of Structural Analysis of Historical Constructions (SAHC)por
dc.subject.wosScience & Technologypor
sdum.conferencePublication8th International Conference of Structural Analysis of Historical Constructions (SAHC)por
sdum.bookTitleSTRUCTURAL ANALYSIS OF HISTORICAL CONSTRUCTIONS, VOLS 1-3por
Aparece nas coleções:ISISE - Comunicações a Conferências Internacionais

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
1639-1646 SAHC2012_108.pdf
Acesso restrito!
1,01 MBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID