Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/20841

TítuloDetorque evaluation of dental abutment screws after immersion in a fluoridated artificial saliva solution
Autor(es)Duarte, Antônio R. C.
Silva Neto, João P.
Souza, J. C. M.
Bonachela, Wellington C.
Palavras-chaveDental abutments
Dental implants
Screw loosening
Torque
Corrosion
Data2013
EditoraWiley
RevistaJournal of Prosthodontics
Resumo(s)Purpose: Implant-abutment connections still present failures in the oral cavity due to the loosening of mechanical integrity by detorque and corrosion of the abutment screws. The objective of this study was to evaluate the detorque of dental abutment screws before and after immersion in fluoridated solutions. Materials and Methods: Five commercial implant-abutment assemblies were assessed in this investigation: (C) Conex˜aoR , (E) EmfilsR , (I) INPR , (S) SINR , and (T) Titanium FixR . The implants were embedded in an acrylic resin and then placed in a holding device. The abutments were first connected to the implants and torqued to 20Ncm using a handheld torque meter. The detorque values of the abutments were evaluated after 10 minutes. After applying a second torque of 20 Ncm, implant-abutment assemblies were withdrawn every 3 hours for 12 hours in a fluoridated solution over a period of 90 days. After that period, detorque of the abutments was examined. Scanning electronicmicroscopy (SEM) associated to energy dispersive spectroscopy (EDS) was applied to inspect the surfaces of abutments. Results: Detorque values of systems C, E, and I immersed in the fluoridated solution were significantly higher than those of the initial detorque. ANOVA demonstrated no significant differences in detorque values between designs S and T. Signs of localized corrosion could not be detected by SEM although chemical analysis by EDS showed the presence of elements involved in corrosive processes. Conclusion: An increase of detorque values recorded on abutments after immersion in fluoridated artificial saliva solutions was noticed in this study. Regarding chemical analysis, such an increase of detorque can result from a corrosion layer formed between metallic surfaces at static contact in the implant-abutment joint during immersion in the fluoridated solutions.
TipoArtigo
DescriçãoArticle first published online: 25 out. 2012
URIhttps://hdl.handle.net/1822/20841
DOI10.1111/j.1532-849X.2012.00941.x
ISSN1532-849X
Versão da editorahttp://onlinelibrary.wiley.com/doi/10.1111/j.1532-849X.2012.00941.x/full
Arbitragem científicayes
AcessoAcesso restrito UMinho
Aparece nas coleções:CT2M - Artigos em revistas de circulação internacional com arbitragem científica

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
DUARTE_Detorque Evaluation of Dental Abutment Screws after immersion in fluoridated solutions.pdf
Acesso restrito!
640,76 kBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID